Cycling Refrigerant Dryers
Installing a refrigeration dryer avoids costly consequences of water in compressed air damage to tools and instruments,
corrosion, air leaks, pressure drop, product spoilage, production downtime and wasted energy.The FT series goes a step further. With its unique energy-saving "TTS" technology, it combines respect for the enviroment with the opportunity for significant reductions in running costs compared to a conventional refrigeration type dryer.
Construction Characteristics
CasingMade from sheet steel panels wich have been phosphated, degreased and polyester powder painted. The panels are not structural elements and are easily removable for service.
Heat Exchanger
The evaporator and the air-to-air heat exchanger (model 009 and above) comprise a single coil with copper tubes and aluminium fins. This makes for an extremely compact and rugged construction. The whole assembly is insulated with high density flameproof polystyrene. The lack of any components subject to particular pressure vessel codes means that the standard model can be used anywhere in the world.
Condenser
Air-cooled by an electric fan fitted with a safety grille. Comprises a painted tubeless steel coil up to model F12T and with copper tubes and aluminium fins for the rest of the range. The location of the condenser in the top section of the dryer ensures it stays cleaner and more efficient for longer.
Refrigerant Compressor
Hermetic, suction gas cooled and protected against thermal and current overloads. The compressor is mounted on anti-vibration rubber supports to ensure quiet running.
Condensate Drain System
The condensate is seperated in a high efficiency stainless steel mesh "demister". Solenoid or optional no-loss capacitance drain.


THAMESAIR LIMITED
UNIT 22, CHENEY MANOR INDUSTRIAL ESTATE
SWINDON, WILTS. SN2 2PJ
WWW.THAMESAIR.COM
TEL: 01793 695095 FAX: 01793 5130907